12-1500VDC
500A
1 form A (SPST-NO)
No polarity
No auxiliary contact, 1 NO
24VDC
Connector
Double coil
Male thread
Bottom mount
Availability: | |
---|---|
Quantity: | |
Main features of energy storage system:
Energy storage system DC contactor high voltage, up to 1500VDC;
The DC contactor of the energy storage system is charged and discharged at the same port;
Dc contactor of energy storage system has long working time and high stability requirement.
Main performance requirements of DC contactor for energy storage system:
The rated working voltage of DC contactor of energy storage system meets 1500VDC;
The main contact of DC contactor of energy storage system has high short-circuit resistance;
The main contact of DC contactor of energy storage system rises at low temperature;
Dc contactor for 500A energy storage system Main contactor Product Features:
The main contact of DC contactor of 500A energy storage system is non-polar, and the function is optional with auxiliary contact, and the state feedback of the main contact is more reliable and direct.
▍Dimension & Wiring
▍Parameters
Contact Parameters | Contact Polar | nonpolarity |
Rating Voltage | 12-1500Vdc | |
Rating Current | 500A (▲1) | |
Current Endurance | 600A 400sec. | |
1000A 40sec. | ||
Break Current, Max, only 1 time | 2500A 320Vdc | |
Contact Resistance | ≤30mΩ (6VDC 20A) (1mΩ) | |
Life | Mechanical Life | 2×105 Times (▲3) |
Electrical Life (▲1, ▲2) | DC750V 500A,1200 Times DC1000V 300A, 1000 Times DC1200V 200A,1200 Times DC1500V 200A,800 Times | |
Coil Parameters | Nominal Voltage | 24Vdc (Us) |
Nominal Current (at 20℃) | 2A | |
Coil Power (at 20℃) | About 6W | |
Coil Polar | × |
▲1:Resistive Load, L/R≤1ms.
▲2:Switching Rating, ON : OFF=1s : 9s.
▲3:Switching Rating, ON : OFF=0.5s : 0.5s.
Main features of energy storage system:
Energy storage system DC contactor high voltage, up to 1500VDC;
The DC contactor of the energy storage system is charged and discharged at the same port;
Dc contactor of energy storage system has long working time and high stability requirement.
Main performance requirements of DC contactor for energy storage system:
The rated working voltage of DC contactor of energy storage system meets 1500VDC;
The main contact of DC contactor of energy storage system has high short-circuit resistance;
The main contact of DC contactor of energy storage system rises at low temperature;
Dc contactor for 500A energy storage system Main contactor Product Features:
The main contact of DC contactor of 500A energy storage system is non-polar, and the function is optional with auxiliary contact, and the state feedback of the main contact is more reliable and direct.
▍Dimension & Wiring
▍Parameters
Contact Parameters | Contact Polar | nonpolarity |
Rating Voltage | 12-1500Vdc | |
Rating Current | 500A (▲1) | |
Current Endurance | 600A 400sec. | |
1000A 40sec. | ||
Break Current, Max, only 1 time | 2500A 320Vdc | |
Contact Resistance | ≤30mΩ (6VDC 20A) (1mΩ) | |
Life | Mechanical Life | 2×105 Times (▲3) |
Electrical Life (▲1, ▲2) | DC750V 500A,1200 Times DC1000V 300A, 1000 Times DC1200V 200A,1200 Times DC1500V 200A,800 Times | |
Coil Parameters | Nominal Voltage | 24Vdc (Us) |
Nominal Current (at 20℃) | 2A | |
Coil Power (at 20℃) | About 6W | |
Coil Polar | × |
▲1:Resistive Load, L/R≤1ms.
▲2:Switching Rating, ON : OFF=1s : 9s.
▲3:Switching Rating, ON : OFF=0.5s : 0.5s.