1. Main features of energy storage system:
Energy storage system DC contactor high voltage, up to 1500VDC;
The DC contactor of the energy storage system is charged and discharged at the same port;
Dc contactor of energy storage system has long working time and high stability requirement.
2. Main performance requirements of DC contactor for energy storage system:
The rated working voltage of DC contactor of energy storage system meets 1500VDC;
The main contact of DC contactor of energy storage system has high short-circuit resistance;
The main contact of DC contactor of energy storage system rises at low temperature;
The main contact of DC contactor of energy storage system is non-polar and has feedback contact.
3. 30A energy storage system precharge contactor Product features:
The rated current of the pre-charged contactor of the 30A energy storage system is 1000VDC.
▍Dimension & Wiring
▍Parameters
Contact Parameters | Contact Polar | nonpolarity |
Rating Voltage | 12-1500Vdc | |
Rating Current | 30A (▲1) | |
Current Endurance | 90A 30sec. | |
150A 10sec. | ||
Break Current, Max, only 1 time | 300A 320Vdc | |
Contact Resistance | ≤30mΩ (6VDC 20A) (1mΩ) | |
Life | Mechanical Life | 2×105 次 (▲3) |
Electrical Life (▲1, ▲2) | DC750V 30A, 1200 次 DC1000V 20A, 400 次 DC1200V 10A, 120次 DC1500V 6A, 100次 | |
Coil Parameters | Nominal Voltage | 24Vdc (Us) |
Nominal Current (at 20℃) | About 143.7mA | |
Coil Power (at 20℃) | About 3.45W | |
Coil Polar | × |
▲1:Resistive Load, L/R≤1ms.
▲2:Switching Rating, ON: OFF=1s : 9s.
▲3:Switching Rating, ON: OFF=0.5s : 0.5s.
1. Main features of energy storage system:
Energy storage system DC contactor high voltage, up to 1500VDC;
The DC contactor of the energy storage system is charged and discharged at the same port;
Dc contactor of energy storage system has long working time and high stability requirement.
2. Main performance requirements of DC contactor for energy storage system:
The rated working voltage of DC contactor of energy storage system meets 1500VDC;
The main contact of DC contactor of energy storage system has high short-circuit resistance;
The main contact of DC contactor of energy storage system rises at low temperature;
The main contact of DC contactor of energy storage system is non-polar and has feedback contact.
3. 30A energy storage system precharge contactor Product features:
The rated current of the pre-charged contactor of the 30A energy storage system is 1000VDC.
▍Dimension & Wiring
▍Parameters
Contact Parameters | Contact Polar | nonpolarity |
Rating Voltage | 12-1500Vdc | |
Rating Current | 30A (▲1) | |
Current Endurance | 90A 30sec. | |
150A 10sec. | ||
Break Current, Max, only 1 time | 300A 320Vdc | |
Contact Resistance | ≤30mΩ (6VDC 20A) (1mΩ) | |
Life | Mechanical Life | 2×105 次 (▲3) |
Electrical Life (▲1, ▲2) | DC750V 30A, 1200 次 DC1000V 20A, 400 次 DC1200V 10A, 120次 DC1500V 6A, 100次 | |
Coil Parameters | Nominal Voltage | 24Vdc (Us) |
Nominal Current (at 20℃) | About 143.7mA | |
Coil Power (at 20℃) | About 3.45W | |
Coil Polar | × |
▲1:Resistive Load, L/R≤1ms.
▲2:Switching Rating, ON: OFF=1s : 9s.