400A 12-1000VDC Coil 12/24/48V High Voltage 72 series DC Contactor

  • 12-1000VDC

  • 400A

  • 1 form A (SPST-NO)

  • No polarity

  • No auxiliary contact, 1 NO

  • 12VDC, 24VDC, 48VDC

  • Connector

  • Single coil

  • Female thread

  • Bottom mount

Availability:
Quantity:


▍Product features

Step 1: Installation

Ensure the 400A contactor is mounted securely in a dry, vibration-free environment. This model is designed for installation in compact spaces, so it’s important to check for proper ventilation to prevent overheating.


Step 2: Wiring

Follow the product's wiring diagram closely. Ensure the correct connection of the 12/24/48V control coil to the system. Improper wiring can result in operational failures.


Step 3: Testing

After installation, run a system test to check for normal contactor operation. Monitor the contactor for any irregular noises or signs of overheating during the initial test run.


Step 4: Regular Maintenance

Perform routine inspections to ensure all connections remain secure and clean. Any dust or debris should be cleared to maintain optimal performance. Lubrication is generally not required due to its low-maintenance design.


▍Coil Data

Coil Voltage Pickup Voltage Dropout Voltage Inrush Current Avg Holding Current Holding Power
12VDC 9VDC Max 1.2VDC Min 3.8A Max

0.5A Approx

6W Max
24VDC 18VDC Max 2.4VDC Min 2A Max

0.25A Approx

6W Max

Remarks:

1. The coil parameter values are theoretical values at an ambient temperature of 20℃, with a variation range of approximately ±10% due to the influence of coil resistance.

2. The reliable working voltage range of the coil is 85%~110% of the rated voltage.

3. If other rated voltages are required,special orders can be made.


▍Main Contact

Contact Arrangement 1 Form A (SPST-NO)
Contact Polarized
Nonpolarized
Contact Resistance (Initial)
1mΩ (Typical Value)
Load Voltage
12-1000VDC
Current (continuous)
400A
Mechanical Life
2×105cycles

Remarks:

1. Resistive load category (L/R<0.1ms).

2. Switching frequency between on and off, ON: OFF=1 sec: 9 sec .

3. The testing environment temperature is 23±5℃.

4. The electrical life is the number of times a product breaks under load.


▍Performance Parameter

Insulation Resistance

1000MΩ@2500VDC (lnitial)

≤50MΩ@1000VDC (End)

Dielectric Withstanding Voltage AC3500V 1min≤10mA
Operate Time 40ms (Include bounce)
Release Time 20ms (Include bounce)
Bounce Time 5ms
Shock 20g peak, 1/2 sine (Operating)
Sine Vibration 20g peak, 80~2000Hz
Humidity 5%~85% RH
Operating Temperature -40℃~+85℃
Weight 890g Approx

Remarks:

1. Apply rated working voltage to the coil without a freewheeling diode.

2. The testing environment temperature is 20℃.

▍Performance Parameter
5-200系列 双线圈_内螺纹 E型                                                          接线图E型 (1)


QUICK LINKS

SEARCH BY VOLTAGE

SEARCH BY INDUSTRY

CONTACT US

 +86-512-66188468
  +86-13338661529
  No.599, Taishan road, Huqiu District, Suzhou city, Jiangsu province China
​Copyright © 2024 Suzhou ALQ Electronic Technology Co., Ltd. All rights reserved. | Sitemap | Privacy Policy