150A 12-1500VDC Coil 12/24V High Voltage DC Contactor

  • 12-1500VDC

  • 150A

  • 1 form A (SPST-NO)

  • No polarity

  • No auxiliary contact, 1 NO

  • 12VDC, 24VDC

  • No connector

  • Single coil

  • Female thread

  • Bottom mount

Availability:
Quantity:


▍Features

1. The product complies with the EU RoHS directive.

2. Hermetically sealed and intrinsically safe. Not mounting position sensitive.

3. Operates in harsh environments without oxidation or contamination of contacts.

4. High voltage isolation between open contacts, inert gas filled contact chamber.

5. Product design and quality control in accordance to lATF-16949.


▍Coil Data

Coil Voltage Pickup Voltage Dropout Voltage Coil Resistance Avg Holding Current Holding Power
12VDC 9VDC Max 1.2VDC Min 25Ω 480mA 5.8W
24VDC 18VDC Max 2.4VDC Min 120Ω 200mA 4.8W

Remarks:

1. The coil parameter values are theoretical values at an ambient temperature of 20℃, with a variation range of approximately ±10% due to the influence of coil resistance.

2. The reliable working voltage range of the coil is 85%~110% of the rated voltage.

3. If other rated votages are required, special orders can be made.


▍Main Contact

Contact Arrangement 1 Form A (SPST-NO)
Contact Polarized
Nonpolarized
Contact Resistance (Initial)
1mΩ (Typical Value)
Load Voltage
12-1500VDC
Current (continuous)
150A
Mechanical Life
2×105cycles
Electrical Life
Graph 1
Overload Current
Graph 2

Remarks:

1. Resistive load category (L/R<0.1ms).

2. Switching frequency between on and off, ON: OFF=1 sec: 9 sec .

3. The testing environment temperature is 23±5℃.

4. The electrical life is the number of times a product breaks under load.


Electrical Life Reference Curve-Graph1

Overload Current vs

Time Reference Curve-Graph2



▍Performance Parameter

3-150 G系列 尺寸图


Fastener
Torque Range
Main contacts wiring
Product mount
M6×12
(Provided)
4.5~6.5N·m
1.8~2.5N·m

100线圈图


▍Performance Parameter

Insulation Resistance

1000MΩ@2500VDC (lnitial)

≤50MΩ@1000VDC (End)

Dielectric Withstanding Voltage AC3500V 1min≤10mA
Operate Time 30ms (Include bounce)
Release Time 12ms (Include bounce)
Bounce Time 5ms
Shock 20g peak, 1/2 sine (Operating)
Sine Vibration 20g peak, 80~2000Hz
Humidity 5%~85% RH
Operating Temperature -40℃~+85℃
Weight 355g Approx

Remarks:

1. Apply rated working voltage to the coil without a freewheeling diode.

2. The testing environment temperature is 20℃.


▍Ordering Information


        EVQ150



   (Rated curent)




              E 



  (Main contacts feature)



         12



  (Coil voltage)



             D


   (Coil lead out)




           A



   (Mounting)




         3 * * *



  (Product code)





"150"=150A


"E"=Non-polarity+No 

auxiliary contact;

"G"=Non-polarity+1NO.

"12"=12VDC 

"24"=24VDC


"D"= Wire Without Connectors;

"E"= Wire With Connectors. (Manufacturer's recommendation).

"A"= Bottom mount

Product code


QUICK LINKS

SEARCH BY VOLTAGE

SEARCH BY INDUSTRY

CONTACT US

 +86-512-66188468
  +86-13338661529
  No.599, Taishan road, Huqiu District, Suzhou city, Jiangsu province China
​Copyright © 2024 Suzhou ALQ Electronic Technology Co., Ltd. All rights reserved. | Sitemap | Privacy Policy