EVQ200G12D01A572000/EVQ250G12D01A572000/EVQ300G12D01A572000/EVQ350G12D01A572000
ALQ
Epoxy Resin Sealing
1000VDC
200A - 350A
Availability: | |
---|---|
Quantity: | |
This product is widely used in the fields of photovoltaics and energy storage. It adopts a double coil innovative design and has a set of feedback contacts built-in. The main contacts achieve non-polarized connection, greatly improving the flexibility of adaptation. At the same time, the product has excellent anti-interference ability and is still stable and reliable in the face of complex electromagnetic environments.
Features
Epoxy packaging, the contacts are protected by nitrogen, preventing oxidation, strong cooling arc capacity.
High-voltage, high-current control capable.
Compact & low operating sound.
Safety and high contact reliability.
Can be installed in any direction.
Not freezing and condensing at low temperature.
Certification
CCC
UL
CE
TUV
Applications
DC Fast charging equipment
Energy storage equipment
Power battery system
High voltage inverter
Power contact
Parameter | Data | ||||||
Contact arrangement | 1 Form X(SPST-NO-DM) | ||||||
Contact polar | Without polarity | ||||||
Contact material | Copper or silver alloy optional, see “Part numbering system” | ||||||
Rated operating voltage | 1,000V DC | ||||||
Max. Continuous current(at 23℃) | 350A | ||||||
Electrical life | Resistive load (R load) L/R ≤ 0.1ms ON : OFF = 1s : 9s | Break | at 350A | at 210A | |||
1,000V DC | 30 cycles | 800 cycles | |||||
750V DC | 100 cycles | 1,500 cycles | |||||
450V DC | 500 cycles | 4,500 cycles | |||||
Capacitive load (C load)(ON : OFF = 1s : 9s)〈01 | Make | 48V DC | 30,000 cycles (at 700A) | ||||
24V DC | 100,000 cycles (at 700A) | ||||||
Max. cut-off current | 2,000A | 1 cycle (at 450V) | |||||
1,000A | 1 cycle (at 750V) | ||||||
500A | 1 cycle (at 1,000V) | ||||||
Mechanical life(ON : OFF = 1s : 9s) | 200,000cycles | ||||||
Initial contact resistance(at 1A) | Max.:30mΩ | Typical:1mΩ | |||||
Operate Time(at 23℃) | Close | 30ms Max.〈02 | |||||
Bounce | 7ms Max. | ||||||
Release | 12ms Max.〈03 |
〈01 Applicable only to DC contactors with power contact materials being silver alloys.
〈02 Coil nominal voltage, includes contact bounce time.
〈03 Coil nominal voltage, includes arcing, without diode.
Auxiliary contact
Parameter | Data |
Contact arrangement〈04 | 1 Form A (SPST-NO) / 1 Form B (SPST-NC) (optional) |
Contact polar | Without polarity |
Contact current, Max. | 2A(at 30V DC) |
3A(at 125V AC) | |
Contact current, Min. | 100mA(at 8V) |
Contact resistance, Max. | 0.417ohms(at 30V DC) |
0.150ohms(at 125V AC) | |
Electrical life(Resistive load, L/R ≤ 0.1ms) | 100,000cycles(at 24V DC/2A) |
〈04 The auxiliary contact is mechanically linked to the main power contacts.
Coil(at 23℃)
Parameter | Data | |
Rated voltage | 12V DC | 24V DC |
Coil type | Dual coil〈05 | |
Pick-up (close) voltage Max.〈06 〈07 | 9V DC | 18V DC |
Drop-out (open) voltage Min.〈06 | 1.2V DC | 2.4V DC |
Pick-up (close) current Max. | 3.8A(75ms Max.)〈08 | 2A(75ms Max.)〈08 |
Holding current (Avg.) | 0.5A(at 12V DC) | 0.25A(at 24V DC) |
Coil power Max.〈06 | 6W(at 12V DC) | 6W(at 24V DC) |
Operating voltage range | 10.2-13.2V DC | 20.4-26.4V DC |
〈05 The product has been configured with coil surge absorption circuit (TVS), buyers do not need to configure.
〈06 Because the DC contactor is operated by a coil that changes resistance with temperature: When the temperature is higher than 23℃, coil resistance, pick-up voltage and drop-out voltage will be higher than the nominal value, and the coil power will be lower than the nominal value. When the temperature is below 23℃, coil resistance, pick-up voltage and drop-out voltage will be lower than the nominal value, and the coil power will be higher than the nominal value.
〈07 For pick-up testing of DC contactors with dual coil, the voltage should not rise slowly, and the voltage should be applied not less than the nominal pick-up voltage immediately. Otherwise, the DC contactor will not pick-up.
〈08 Contactor has two coils. Both are used for pick-up, and then in approximately 75 milliseconds, one coil is electronically removed from the coil drive circuit. The remaining coil supplies low continuous hold power sufficient for the contactor to meet all its specified performance specifications. This provides the lowest coil power.
Insulation
Parameter | Data | |
Insulation resistance(at 1000V DC)〈09 | Initial:100MΩ Min. | |
End of life:50MΩ Max. | ||
Dielectric withstanding voltage (at sea level) | Between open contacts | AC 3,500 Vrms for 1min.〈10 |
Between contacts and coil |
〈09 Measurement at same location as "Dielectric withstanding voltage" section.
〈10 Leakage current:10mA
Environmental
Parameter | Data | |
Shock(1/2 Sine, 11ms) | Actuated (closed) | 20G |
Non-Actuated (open) | 20G | |
Vibration, Sinusoidal(80-2000Hz Peak) | 20G | |
Environmental seal | IP67 & IP69K | |
Salt fog | MIL-STD-810 | |
Operating ambient temp range | -40℃ to +85℃ | |
Storage ambient temp range | -70℃ to +85℃ | |
Ambient humidity | 5%~95% RH | |
Altitude | ≤4000m |
This product is widely used in the fields of photovoltaics and energy storage. It adopts a double coil innovative design and has a set of feedback contacts built-in. The main contacts achieve non-polarized connection, greatly improving the flexibility of adaptation. At the same time, the product has excellent anti-interference ability and is still stable and reliable in the face of complex electromagnetic environments.
Features
Epoxy packaging, the contacts are protected by nitrogen, preventing oxidation, strong cooling arc capacity.
High-voltage, high-current control capable.
Compact & low operating sound.
Safety and high contact reliability.
Can be installed in any direction.
Not freezing and condensing at low temperature.
Certification
CCC
UL
CE
TUV
Applications
DC Fast charging equipment
Energy storage equipment
Power battery system
High voltage inverter
Power contact
Parameter | Data | ||||||
Contact arrangement | 1 Form X(SPST-NO-DM) | ||||||
Contact polar | Without polarity | ||||||
Contact material | Copper or silver alloy optional, see “Part numbering system” | ||||||
Rated operating voltage | 1,000V DC | ||||||
Max. Continuous current(at 23℃) | 350A | ||||||
Electrical life | Resistive load (R load) L/R ≤ 0.1ms ON : OFF = 1s : 9s | Break | at 350A | at 210A | |||
1,000V DC | 30 cycles | 800 cycles | |||||
750V DC | 100 cycles | 1,500 cycles | |||||
450V DC | 500 cycles | 4,500 cycles | |||||
Capacitive load (C load)(ON : OFF = 1s : 9s)〈01 | Make | 48V DC | 30,000 cycles (at 700A) | ||||
24V DC | 100,000 cycles (at 700A) | ||||||
Max. cut-off current | 2,000A | 1 cycle (at 450V) | |||||
1,000A | 1 cycle (at 750V) | ||||||
500A | 1 cycle (at 1,000V) | ||||||
Mechanical life(ON : OFF = 1s : 9s) | 200,000cycles | ||||||
Initial contact resistance(at 1A) | Max.:30mΩ | Typical:1mΩ | |||||
Operate Time(at 23℃) | Close | 30ms Max.〈02 | |||||
Bounce | 7ms Max. | ||||||
Release | 12ms Max.〈03 |
〈01 Applicable only to DC contactors with power contact materials being silver alloys.
〈02 Coil nominal voltage, includes contact bounce time.
〈03 Coil nominal voltage, includes arcing, without diode.
Auxiliary contact
Parameter | Data |
Contact arrangement〈04 | 1 Form A (SPST-NO) / 1 Form B (SPST-NC) (optional) |
Contact polar | Without polarity |
Contact current, Max. | 2A(at 30V DC) |
3A(at 125V AC) | |
Contact current, Min. | 100mA(at 8V) |
Contact resistance, Max. | 0.417ohms(at 30V DC) |
0.150ohms(at 125V AC) | |
Electrical life(Resistive load, L/R ≤ 0.1ms) | 100,000cycles(at 24V DC/2A) |
〈04 The auxiliary contact is mechanically linked to the main power contacts.
Coil(at 23℃)
Parameter | Data | |
Rated voltage | 12V DC | 24V DC |
Coil type | Dual coil〈05 | |
Pick-up (close) voltage Max.〈06 〈07 | 9V DC | 18V DC |
Drop-out (open) voltage Min.〈06 | 1.2V DC | 2.4V DC |
Pick-up (close) current Max. | 3.8A(75ms Max.)〈08 | 2A(75ms Max.)〈08 |
Holding current (Avg.) | 0.5A(at 12V DC) | 0.25A(at 24V DC) |
Coil power Max.〈06 | 6W(at 12V DC) | 6W(at 24V DC) |
Operating voltage range | 10.2-13.2V DC | 20.4-26.4V DC |
〈05 The product has been configured with coil surge absorption circuit (TVS), buyers do not need to configure.
〈06 Because the DC contactor is operated by a coil that changes resistance with temperature: When the temperature is higher than 23℃, coil resistance, pick-up voltage and drop-out voltage will be higher than the nominal value, and the coil power will be lower than the nominal value. When the temperature is below 23℃, coil resistance, pick-up voltage and drop-out voltage will be lower than the nominal value, and the coil power will be higher than the nominal value.
〈07 For pick-up testing of DC contactors with dual coil, the voltage should not rise slowly, and the voltage should be applied not less than the nominal pick-up voltage immediately. Otherwise, the DC contactor will not pick-up.
〈08 Contactor has two coils. Both are used for pick-up, and then in approximately 75 milliseconds, one coil is electronically removed from the coil drive circuit. The remaining coil supplies low continuous hold power sufficient for the contactor to meet all its specified performance specifications. This provides the lowest coil power.
Insulation
Parameter | Data | |
Insulation resistance(at 1000V DC)〈09 | Initial:100MΩ Min. | |
End of life:50MΩ Max. | ||
Dielectric withstanding voltage (at sea level) | Between open contacts | AC 3,500 Vrms for 1min.〈10 |
Between contacts and coil |
〈09 Measurement at same location as "Dielectric withstanding voltage" section.
〈10 Leakage current:10mA
Environmental
Parameter | Data | |
Shock(1/2 Sine, 11ms) | Actuated (closed) | 20G |
Non-Actuated (open) | 20G | |
Vibration, Sinusoidal(80-2000Hz Peak) | 20G | |
Environmental seal | IP67 & IP69K | |
Salt fog | MIL-STD-810 | |
Operating ambient temp range | -40℃ to +85℃ | |
Storage ambient temp range | -70℃ to +85℃ | |
Ambient humidity | 5%~95% RH | |
Altitude | ≤4000m |