English
Home » Products » DC Contactor » 200A - 350A Rated Current » 200A 250A 300A 350A 1000VDC High voltage DC contactor specially designed for Charging Station

SEARCH BY FAMILY

SEARCH BY VOLTAGE

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

200A 250A 300A 350A 1000VDC High voltage DC contactor specially designed for Charging Station

  • EVQ200G12D01A572000/EVQ250G12D01A572000/EVQ300G12D01A572000/EVQ350G12D01A572000

  • ALQ

  • Epoxy Resin Sealing

  • 1000VDC

  • 200A - 350A

Availability:
Quantity:

This product is widely used in the fields of photovoltaics and energy storage. It adopts a double coil innovative design and has a set of feedback contacts built-in. The main contacts achieve non-polarized connection, greatly improving the flexibility of adaptation. At the same time, the product has excellent anti-interference ability and is still stable and reliable in the face of complex electromagnetic environments.


Features

Epoxy packaging, the contacts are protected by nitrogen, preventing oxidation, strong cooling arc capacity.

High-voltage, high-current control capable.

Compact & low operating sound.

Safety and high contact reliability.

Can be installed in any direction.

Not freezing and condensing at low temperature.


Certification

CCC

UL

CE  

TUV


Applications

DC Fast charging equipment

Energy storage equipment

Power battery system

High voltage inverter


Power contact

Parameter

Data

Contact arrangement

1 Form X(SPST-NO-DM)

Contact polar

Without polarity

Contact material

Copper or silver alloy optional, see “Part numbering system”

Rated operating voltage

1,000V DC

Max. Continuous current(at 23℃)

350A

Electrical life


Resistive load (R load)

L/R ≤ 0.1ms

ON : OFF = 1s : 9s

Break


at 350A

at 210A

1,000V DC

30 cycles

800 cycles

750V DC

100 cycles

1,500 cycles

450V DC

500 cycles

4,500 cycles

Capacitive load (C load)(ON : OFF = 1s : 9s)〈01

Make

48V DC

30,000 cycles    (at 700A)

24V DC

100,000 cycles   (at 700A)

Max. cut-off current

2,000A

1 cycle  (at 450V)

1,000A

1 cycle  (at 750V)

500A

1 cycle  (at 1,000V)

Mechanical life(ON : OFF = 1s : 9s)

200,000cycles

Initial contact resistance(at 1A)

Max.:30mΩ

Typical:1mΩ

Operate Time(at 23℃)

Close

30ms Max.〈02

Bounce

7ms Max.

Release

12ms Max.〈03

〈01 Applicable only to DC contactors with power contact materials being silver alloys.

〈02 Coil nominal voltage, includes contact bounce time.

〈03 Coil nominal voltage, includes arcing, without diode.


Auxiliary contact

Parameter

Data

Contact arrangement〈04

1 Form A (SPST-NO) / 1 Form B (SPST-NC) (optional)


Contact polar

Without polarity

Contact current, Max.

2A(at 30V DC)

3A(at 125V AC)

Contact current, Min.

100mA(at 8V)

Contact resistance, Max.

0.417ohms(at 30V DC)

0.150ohms(at 125V AC)

Electrical life(Resistive load, L/R ≤ 0.1ms)

100,000cycles(at 24V DC/2A)

〈04 The auxiliary contact is mechanically linked to the main power contacts.


Coilat 23℃)

Parameter

Data

Rated voltage

12V DC

24V DC

Coil type

Dual coil〈05

Pick-up (close) voltage Max.〈06 〈07

9V DC

18V DC

Drop-out (open) voltage Min.〈06

1.2V DC

2.4V DC

Pick-up (close) current Max.

3.8A(75ms Max.)〈08

2A(75ms Max.)〈08

Holding current (Avg.)

0.5A(at 12V DC)

0.25A(at 24V DC)

Coil power Max.〈06

6W(at 12V DC)

6W(at 24V DC)

Operating voltage range

10.2-13.2V DC

20.4-26.4V DC


〈05 The product has been configured with coil surge absorption circuit (TVS), buyers do not need to configure.

〈06 Because the DC contactor is operated by a coil that changes resistance with temperature: When the temperature is higher than 23℃, coil resistance, pick-up voltage and drop-out voltage will be higher than the nominal value, and the coil power will be lower than the nominal value. When the temperature is below 23℃, coil resistance, pick-up voltage and drop-out voltage will be lower than the nominal value, and the coil power will be higher than the nominal value.

〈07 For pick-up testing of DC contactors with dual coil, the voltage should not rise slowly, and the voltage should be applied not less than the nominal pick-up voltage immediately. Otherwise, the DC contactor will not pick-up.

〈08 Contactor has two coils. Both are used for pick-up, and then in approximately 75 milliseconds, one coil is electronically removed from the coil drive circuit. The remaining coil supplies low continuous hold power sufficient for the contactor to meet all its specified performance specifications. This provides the lowest coil power.


Insulation

Parameter

Data

Insulation resistance(at 1000V DC)〈09

Initial:100MΩ Min.

End of life:50MΩ Max.

Dielectric withstanding voltage

(at sea level)

Between open contacts

AC 3,500 Vrms for 1min.〈10

Between contacts and coil

〈09 Measurement at same location as "Dielectric withstanding voltage" section.

〈10 Leakage current:10mA


Environmental

Parameter

Data

Shock(1/2 Sine, 11ms)

Actuated (closed)

20G

Non-Actuated (open)

20G

Vibration, Sinusoidal(80-2000Hz Peak)

20G

Environmental seal

IP67 & IP69K

Salt fog

MIL-STD-810

Operating ambient temp range

-40℃ to +85℃

Storage ambient temp range

-70℃ to +85℃

Ambient humidity

5%~95% RH

Altitude

≤4000m

EVQ350_5E_(1,000Vdc-350A)_ALQ-SPEC-004_V03 1EVQ350_5E_(1,000Vdc-350A)_ALQ-SPEC-004_V03 2EVQ350_5E_(1,000Vdc-350A)_ALQ-SPEC-004_V03 3EVQ350_5E_(1,000Vdc-350A)_ALQ-SPEC-004_V03 4EVQ350_5E_(1,000Vdc-350A)_ALQ-SPEC-004_V03 5

FAQ


QUICK LINKS

SEARCH BY SERIES

CONTACT US
 +86-512-66188458
  +86-13338661529
  No.599, Taishan road, Huqiu District, Suzhou city, Jiangsu province China
Copyright © 2025 Suzhou ALQ Electronic Technology Co., Ltd. All rights reserved.   | Sitemap | Privacy Policy